Filter Results By:

Products

Applications

Manufacturers

Showing results: 136 - 150 of 158 items found.

  • Alarms

    DEVAR Inc.

    Devar alarms are designed to accurately monitor process trip-points from current, millivolt, DC volts and thermocouple signals. These alarm points can be easily set in percent of signal or directly in engineering units. The units will constantly monitor the set point against the actual signal and switch a 10 amp SPDT relay when the set point is exceeded. Alarms are available in wall mount, panel mount, track or DIN rail mount, AC/DC line voltage powered or loop powered versions.

  • Precision Current & Voltage & Thermocouple Source/Measure Calibrator

    Extech PRC30 - Extech Instruments Corporation

    The PRC30 is a Multifunction Process Calibrator. This calibrator provides precision sourcing and measurements for thermocouples (eight types), current (mA), and voltage (mV and V) devices. Featuring 24 volt loop power, five user adjustable calibration presets, and temperature output in Fahrenheit, Celsius, and millivolts. Product includes test leads, alligator clips, thermocouple calibration cable, universal calibration cable, 100-240V AC universal adapter with 4 plugs, AA batteries, hard case, and user manual.

  • Rechargeable Multifunction Tester

    ET4000 - Martindale Electric Co. Ltd

    The new ET4000 tester carries out all the tests needed to verify the safety of electrical installations in domestic, commercial and industrial wiring installations in accordance with the latest regulations.

    Everything about the new ET Series has been designed to save time and make testing easier.

    Fast, reliable high current and non-trip loop testing comes as standard together with a high level of input protection and a CAT IV safety rating .

    Supplied with a full range of accessories.

  • 4 High-Voltage/High-Current (External VCC) D/A Outputs

    DA5 - North Atlantic Industries

    Digital-to-Analog (D/A) module DA5 provides 4 independent D/A output channels (half-bridge) utilizing a single external supplied power source with full-scale operating range of 0-65 VDC (V-control mode) and 0-2 A (I-control mode). Alternatively, two channels can be paired (full-bridge) to achieve a full-scale operating range of ±65 V and ±2 A from a single external supplied power source. Linearity/accuracy is ±1% FS range over temperature. The DA5 provides either voltage or current control loop modes, which are programmable for the application.

  • Pressure Calibrators

    AMETEK Sensors, Test & Calibration

    Our pressure calibrators offer a wide variety of features, accuracies, and pressure ranges. Included are intrinsically safe percent of reading calibrators, reference data recorders, wide-range dual sensor calibrators, and calibrators with built in pressure pumps. Many of our calibrators also offer current measurement, voltage measurement, 24 volt loop power supplies, and even complete systems with pressure pumps and calibration software. In many cases, one handheld calibrator can replace multiple instruments, reducing ongoing recalibration and maintenance costs.

  • sbRIO-9265, Non-Enclosed, 4-Channel C Series Current Output Module

    780921-01 - NI

    Non-Enclosed, 4-Channel C Series Current Output Module - The sbRIO‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The sbRIO‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity. Non-enclosed modules are designed for OEM applications.

  • Multifunction Electrical Installations Meter

    MPI-520S - Sonel S.A.

    The MPI-520S multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520S is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.

  • Event Detectors

    105/106 Series - Analysis Tech Inc.

    The 105/106 Series Event Detectors are the most versatile Event Detectors in the product line. These Event Detectors monitor the electrical resistance of up to 128 simple continuity loops, each comprised of single or multiple specimens under test. Each test specimen is continuously monitored while a selectable DC sense current is passed through each channel test-loop; resistance changes exceeding the selected threshold are recorded as an event. Minimum Event Duration, Channel Current, and Threshold Voltage settings can all be independently configured. 105 and 106 Series instruments are electrically identical, with the difference simply that the 105 offers four, 32-channel board slots and the 106 offers only one. Thus the 128-105 is equivalent to four 32-106 Event Detectors.

  • 4-Port Serial Interface

    APCI-7500-3 - TEAM SOLUTIONS, INC.

    This Model has a 37-pin D-Sub male connectorRS232, RS422, RS485, 20 mA Current LoopModular structure through SI modulesWith or without optical isolationMode configuration free for each port128-byte FIFO-buffer, common interruptTransfer rate programmable up to 115,200 BaudOption: up to 1 MBaud for RS485 and RS422Automatic direction recognition for RS48Mode: configurable RS232, RS422, RS485, 20 mA Current Loop (active, passive) with or without isolation (SI modules)Transmission mode asynchronous, full, half duplexTransfer rate: progr. up to 115.2 kBaud up to 1 MBaud on requestProtocol: 5, 6, 7 or 8-bit character 1, 1? or 2 stop bitsParity: even, odd, none, mark or spaceInterrupt lines: automatic through BIOS

  • High-accuracy Dual-channel Programmable Battery Simulator

    N8352 Series - Next Generation Instrumental (Shanghai) T&C Tech. Co., Ltd.

    N8352 series is specially designed for the R&D and testing of portable, battery-operated products , such as Bluetooth headsets, mobile, AR/VR smart terminals, electrical tools, etc. The current flows in both directions and can be used as either a power supply or a load. N8352 is easy for operation with touch screen and UI design. The output features are comparable to actual batteries, with fast dynamic response, no overshoot in voltage rise and fall, and stable waveform. The resolution is up to nA level, which can test the loop static power consumption, etc. N8352 can be widely used in the area of consumer electronics testing.

  • Microwave Moisture Meter

    RX-95 - Resonance Technology

    The system works based on the absorption of microwave energy by water molecules contained inthe x-rayed material. It is a non-contact, non-destructive method of instant measurement of water content - used for materials such as coal, flour, grain, cement, seeds, sugar, etc. Thanks to high measurement sensitivity (resolution greater than 0.01% of water content by weight), short measurement time (about 5 times/sec.) and repeatability of measurement - the system is suitable for continuous measurement of material moisture, e.g. on conveyor belts and its recording on a PC or using a 4-20 mA current loop.

  • Multi-Zone Gas Monitor

    HGM-MZ - IMR Environmental Equipment, Inc.

    The Multi-Zone Monitor provides continuous detection of refrigerant gas levels in up to 16 separate test zones and can be fitted with an optional two channel 4-20 mA current loop board for connection to remote monitoring equipment. Multi-Zone monitors retain a log of previous readings that can be easily accessed for analysis. Four relay contacts are provided that can be programmed to trigger external alarm devices in the event of a system fault, or if a leak (small), spill (medium) or evacuation (large) level of gas is detected, while audible and visual front panel indicators show alarm and fault conditions.

  • Toxic Gas Sensor

    Model 100 - Teledyne Gas & Flame Detection

    Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel. Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.

  • Industrial 4-20mA Driver

    Analog Devices Inc.

    Analog Devices portfolio of leading industrial d/a converters and drivers addresses the challenges of enhancing system accuracy, reliability, and overall functionality while reducing form factor and power dissipation. The products provide a range of programmable output ranges from standard 4–20 mA for current loop communication to ±10 V for actuator control. They simplify industrial system design by offering considerable control functionality and advanced on-chip diagnostics to maximize system up time. ADI industrial converters also eliminate the need for costly calibration routines needed by some traditional discrete architectures.

  • Industrial 4-20mA DAC Solution

    Analog Devices Inc.

    Analog Devices portfolio of leading industrial digital-to-analog converters address the challenges of enhancing system accuracy, reliability, and overall functionality while reducing form factor and power dissipation. The products provide a range of programmable output ranges from standard 4–20 mA for current loop communication to ±10 V for actuator control. They simplify industrial system design by offering considerable control functionality and advanced on-chip diagnostics to maximize system up time. ADI industrial converters also eliminate the need for costly calibration routines needed by some traditional discrete architectures.

Get Help